IBM 3197 Terminal

 
 
 
 



3197-C10 Twinax Color Terminal with Keyboard
Fully refurbished with 90-day warranty
3197-C10

Retired, no longer available: Contact for alternatives


3197-C20 Twinax Color Terminal with Keyboard
Fully refurbished with 90-day warranty
3197-C20

Retired, no longer available: Contact for alternatives


3197-D10 Twinax Monochrome Terminal with Keyboard
Fully refurbished with 90-day warranty
3197-D10

Retired, no longer available: Contact for alternatives


Please note, these terminals  are 30+ years old and are usually bad because of failed power supplies. We suggest instead these-->

Click here for alternative 1

Click here for alternative 2

The IBM 3197 Display Station is for use with the IBM System/36, System/38, AS/400, and the 5294 or 5394 Remote Control Unit. The 3197 is an attractively priced, 14-inch or 15-inch CRT display station with a smudge-resistant screen capable of displaying up to 3,564 characters. Standard features include host-directed alphanumeric print support for IBM ASCII printers, 4201 Proprinter - all models, 4202 Proprinter XL - all models, 4207 Proprinter X24E Model 2, 4208 Proprinter XL24E Model 2, 5202 Quietwriter III printer, 5201 Models 1 and 2 Quietwriter, and the ability to support two display sessions or one display and one printer session concurrently.

The IBM 3197 model C10 display station displays up to 1,920 characters in one of three screen formats and provides a 122-Key Typewriter Keyboard. For administrative purposes, the Model C10 is designated as Model C1Z when ordered as an optional device as part of the System/36 Total System Package (see 5360 and 5362 Sales Manual pages.)

The IBM 3197 model C20 display station displays up to 1,920 characters and provides an IBM Enhanced Keyboard (102-Key).

The IBM 3197 model D10 display station displays up to 3,564 characters in one of three screen formats and provides a 122-Key Typewriter Keyboard. For administrative purposes, the Model D10 is designated as Model D1Z when ordered as an optional device as part of the System/36 Total System Package (see 5360 and 5362 Sales Manual pages.)

The IBM 3197 model D20 display station displays up to 3,564 characters in one of three screen formats and provides an IBM Enhanced Keyboard (102-Key). Model Abstract 3197-DD0The IBM 3197 model DD0 display station displays up to 3,564 characters in one of three screen formats and provides a 122-Key Typewriter Keyboard. For administrative purposes, the Model D10 is designated as Model D1Z when ordered as an optional device as part of the System/36 Total System Package (see 5360 and 5362 Sales Manual pages.)

The IBM 3197 model D40 display station has a 15-inch Green Phosphor monitor and a US English Data Entry 122-Key Keyboard. Model Abstract 3197-DG0The IBM 3197 model DG0 display station has a 15-inch Green Phosphor monitor and a US English Data Entry 122-Key Keyboard.


Highlights

  • Improved price/performance -- low price with discounts for volume procurement
  • Compatibility with existing 3179-2 application programs
  • Functional Enhancements
    • Printer support for host-directed printing
      • 4201 Proprinter (all models) - multi-speed, wire matrix, near-letter quality
      • 4202 Proprinter XL (all models) - wide carriage, multi-speed, wire matrix, near-letter quality
      • 4207 Proprinter X24E - multi-speed, wire matrix, letter quality
      • 4208 Proprinter SL24E Model 2 only - wide carriage multi-speed, wire matrix, letter quality
      • 5201 Models 1 (NO LONGER AVAILABLE) and 2 Quietwriter non-impact, letter quality
      • 5202 Quietwriter III printer non-impact, quiet, letter quality
      • 5204 Quickwriter, if 3197 Display Station has 5256 or 4214 printer emulation
    • Dual address terminal capability when printer is not in use
      • Two concurrent sessions to S/36 or S/38
  • Choice of two keyboards
  • Improved ergonomics/usability
    • Tilt/Swivel pedestal
    • Reduced weight
    • Reduced glare screen
    • Low-profile keyboard with 2 angles of inclination
    • 1,500-Keystroke Record/Play capability
    • Set-up function
    • Keylock
    • Enhanced diagnostics
Model Highlights 3197-W10
  • Full-screen black-on-white presentation
    • 15-inch CRT
    • Reverse Image capability
    • Compatibility with existing 3197-D application programs
  • Local Screen Print
    • Print Screen Trim feature
  • Dual address terminal capability
    • One or two concurrent display sessions to S/36, S/38, or AS/400
    • One display session and one printer session to S/36, S/38, or AS/400
  • Three screen capacities
    • 1,920-character screen (80 columns by 24 rows) plus Operator Information Area and Message Line
    • 3,564-character screen (132 columns by 27 rows) plus Operator Information Area and Message Line
  • In dual address mode, 1,920 and 1,360 character split screen plus Operator Information Area and Message Line
    Description
    The 3197 Model C Color Display Station displays up to 1,920 characters -- 24 lines of 80 characters each plus an Operator Information Area.

    The 3197 Model D and Model W Display Station displays up to 3,564 characters in one of three selectable formats:

    1. Up to 1,920 characters - 24 lines of 80 characters each
    2. Up to 3,564 characters - 27 lines of 132 characters each
    3. In dual address mode, up to 3,280 characters in two split screens - 24 lines of 80 characters each and 17 lines of 80 characters each.
    The 3197 Display Station is used with the Sytem/36, System/38, AS/400, 5294, or 5394 Remote Control Unit.

    In addition, each of the above formats provides operator message and status lines.

    The printer port emulates IBM workstation printers in alphanumeric characters only (5256 or 4214-2) for attached printers which are 4201 Proprinter - all models, 4202 Proprinter XL - all models, 4207 Proprinter X24E Model 2, 4208 Proprinter XL24E Model 2 5202 Quietwriter III printer, or 5201 Models 1 (NO LONGER AVAILABLE) and 2 Quietwriter printer. The attached printer is addressable from the host (programs and other workstations).

    The dual address capability allows two concurrent sessions to S/36, S/38, or AS/400. The prime workstation address is assigned to the display and the second is assigned to either the printer (D-P mode) or display (D-D mode). In D-D mode, two jobs are controlled concurrently and a user may alternate between screens from each session through the use of a "hot key".

    The 3197-C offers functions equivalent to the 3179-2. In addition, the 3197-C offers the ability to attach a choice of printers and to operate in dual terminal mode when the printer is not in use.

    The 3197-D offers functions equivalent to the 3180-2. In addition, the 3197-D offers the ability to attach a choice of printers and to operate in dual terminal mode when the printer is not in use.

    Cable-Thru with Auto-Termination and Screen Glare Reduction are standard. Display functions include: non-display, blinking, underscore, column separator, and reverse image (dark characters on a color background) on a field basis. An operator-adjustable alarm is provided to alert the operator to special conditions. The low-profile keyboard with adjustable slope and 24 application-assigned command functions provides input and control flexibility. Easy-to-use select options, provided from the keyboard, allow the operator to utilize a block or underscore cursor, cursor blink or non-blink. The operator can also elect to display the cursor locations (row/column) and screen attribute codes being utilized as well as set the audible alarm volume.

    The 3197 uses field formatting capability which permits individual fields of data on the screen to be program-defined with various attributes such as protected/unprotected, alphanumeric, normal/intensified, and displayable/non-displayable.

    The 3197 consists of three workstation elements (WSEs): video, logic and keyboard elements.

    Operator Factors

    The 3197 has an etched screen, which minimizes glare and fingerprints. Indicators are displayed in symbols on the bottom row of the screen, outside the data area, and provide useful operator information. Updating the screen from the host is accomplished without refresh interruption (i.e., no blinking). An underline type cursor and a rectangular reverse video cursor, with blinking option are provided. An audible alarm is provided to alert the operator. The volume of the alarm can be adjusted by the operator. The cable-connected keyboard can be moved and the video element can be tilted and swiveled to change the screen angle for the operator. The keyboard slope can be adjusted by the user to 6 or 12 degrees.

    Field Editing

    Individual data input fields can be edited as Alphanumeric, Alpha Only, Digits only, Numeric Only, Signed Numeric, Field Exit Required, Right Adjust, Mandatory Entry, Mandatory Fill, Bypass, Auto Enter, Dup Enable and Monocase.

    Cabling

    The cable attachment between the 3197 and other 5250 system components and/or systems may be made with IBM Cabling System, twinaxial cable, or equivalent. Cable connection: maximum length of any one twinaxial cable is 1,525m (5,000 feet). Up to seven workstations may be attached to a twinaxial cable via the Cable-Thru capability of the 3197-C. See "IBM 5250 Information Display System Planning and Site Preparation Guide", GA21-9337, for cabling information.

    The 3197 may also be attached through existing telephone twisted-pair wiring that meets the IBM Type 3 Media Specification. For proper identification, installation, and application of cable and associated accessories, refer to the "IBM 5299 Model 3, Terminal Multi-connector and Telephone Twisted-pair Planning, Setup, and Maintenance Guide", GA27-3749.

    Security Facilities

    A special non-displayed input mode provides for fields of data to be program-defined so that they will accept data entered from the keyboard without displaying the data on the screen. A Security Keylock prevents modification or display of the data in the display terminal if the key is turned to the "LOCKED" position.

    These capabilities and the terminal's ability to identify itself to the host program, allow customer-supplied security program routines to control access to data and audit of actions.

    User management is responsible for evaluation, selection, and implementation of the security and auditability features, for administrative procedures, and for appropriate controls in application systems. If sensitive data is sent over external communication facilities, user management may wish to pursue the application of cryptography. For more information on data security controls, see "Data Security Controls and Procedures", G320-5649.

    Keyboards

    • 122-Key Typewriter Keyboard - Moveable with 49 alphanumeric keys, 31 control keys, 24 individual Program Command keys, and 18 numeric pad keys.
    • IBM Enhanced Keyboard (Except Canada) 103-Key; (Canada Only) 102-key English, 103-key Canadian/French; typewriter-like layout, moveable with 48 alphanumeric keys, 24 control keys, 12 Program Function keys (24 functions) and 18 numeric pad keys.
      Model Summary Matrix
           Max Display  Monitr    Monitor
    Model Characters Size Color Keyboard Warranty
    ----- ----------- ------ ----------- ---------------------- --------
    C10 1,920 14-in. color 122/124-key Typewriter 1 yr
    C20 1,920 14-in. color 102/104-key Enhanced 1 yr
    CD0 1,920 14-in. color 122-key Typewriter 3 yr CE0 1,920 14-in. color 102-key Enhanced 3 yr
    D10 3,564 15-in. green phos 122/124-key Typewriter 1 yr D20 3,564 15-in. green phos 102/103/104-key Enhancd 1 yr
    DD0 3,564 15-in. green phos 122-key Typewriter 3 yr DE0 3,564 15-in. green phos 102-key Enhanced 3 yr
    D40 3,564 15-in. green phos 122-key US Data Entry -- DG0 3,564 15-in. green phos 102-key US Data Entry -- Customer Setup (CSU)The 3197 is a Customer Setup (CSU) machine. Set-up instructions are included with each machine as "3197 Model C Color Display Station Setup Instructions", (GA18-2558).

    Customer Responsibilities

  • Adequate site, system and other vendor preparation.
  • Receipt at customer's receiving dock, unpacking and placement of unit.
  • During initial set-up, install Repair Identification (RID) tags on each element (logic, video, and keyboard) of the 3197.
  • Physical set-up, connection of cables in customer access areas, switch settings and checkout.
  • Contacting IBM Service for attachment of the 3197 communications cable to an on-site serviced IBM control unit where customer access area is not provided.
  • Determination of the required number of spares.
  • Calling the National Support Center on a toll-free number for service.
  • Returning security keys to IBM if any exchange service of Logic WSE is required. (If the keys are not returned to IBM, the customer will be charged for the replacement of the security keys and locks on a time-and- material basis.)
  • Each customer must order the "3197 Display Station Description," GA18-2544, for site planning and preparation works since this is not shipped with each machine.
    Technical Description Physical SpecificationsVideo Element
    Width:  383mm (15.1 in.)
    Depth: 405mm (15.9 in.)
    Height: 345mm (13.6 in.)
    Weight: 12.7kg (28.0 lbs.)
    Logic Element
    Width:  300mm (11.8 in.)
    Depth: 290mm (11.4 in.)
    Height: 47mm (1.9 in.)
    Weight: 1.2kg ( 2.6 lbs.)
    Video, Pedestal, Logic
    Width:  383mm (15.1 in.)
    Depth: 405mm (15.9 in.)
    Height: 415mm (16.3 in.)
    Weight: 14.5kg (31.9 lbs.)
    Keyboard Element - 122-Key
    Width:  561mm (22.1 in.)
    Depth: 230mm (9.1 in.)
    Height: 30mm (1.2 in.)*
    Weight: 3.0kg (6.6 lbs.)
    Keyboard Element - 102-Key
    Width:  492mm (19.4 in.)
    Depth: 210mm (8.3 in.)
    Height: 30mm (1.2 in.)*
    Weight: 2.4kg ( 5.3 lbs.)
    * At home row Operating EnvironmentOperating environment of configurable I/O units are different.
    • 3197
      • Temperature - Class C: 10 to 40.6C (50 to 105F)
      • Relative Humidity - 8 to 80 percent
    • 4201, 4202, 5201, 5202
      • Temperature - Class B: 15.6 to 32.2C (60 to 90F)
      • Relative Humidity - 20 to 80 percent
    Limitations
    • 4214 printer emulation does not support the Load Alternate Character (LAC) command. As a result, S/36 and S/38 applications which generate graphics for a 4214 printer are not supported on the 3197-D attached printers including:
      • S/36 Advanced Printer Function, Licensed Program (5727-AP1/AP6)
      • S/36 Business Graphics Utilities, Licensed Program (5727-BG1/BG6)
      • S/38 Advanced Printer Function Utility, Licensed Program (5714-UT2)
      • S/38 Business Graphics Utility, Licensed Program (5714-GP1)
      • S/38 GDDM
    • Also, see "Prerequisites"
    • Model D: The following is not available:
      • Reverse Image Key
    Hardware Requirements
  • The 3197 Models C10/CD0, C20/CE0 attach to the S/36, S/38, or 5294 Remote Control Unit via IBM Cabling System, twinaxial cable, or equivalent.

    The 3197 Models D10/DD0, D20/DE0 attach to the S/36, S/38, AS/400, 5294 or 5394 Remote Control Unit via IBM Cabling System, twinaxial cable, or equivalent.

    The 3197-W attaches directly to S/36, S/38, or AS/400 processors. It also attaches remotely to these systems via a 5294 or 5394 Remote Control Unit. Attachment is by the same type of cable as is used to attach a 3196, 3179-2, 3180-2, 3197-C/D, and other 5250 Information Display System devices.

    Programming support or feature prerequisites are:

    • S/36: Release 5.0 or higher
    • S/38: Release 8.0 or higher
    • AS/400: Release 1 or later
    • 5294: For the 3197 Models C10/CD0, Applicable host requirements (see above).
      For the 3197 Model C20 Feature Code #3630 - IBM Enhanced Keyboard Support Feature.

      Note:Feature Code #3630 requires prerequisite #3611 - Feature Adapter Card A.

    • 5394: Applicable host requirements (see above).
    • To attach the 3197 Model C20, CE0 to System/38, the WSCE (WorkStation Controller Extended) is required.
    5202 Quietwriter(R) III Printer

    For full-character-set support, and IBM Electronic III cartridge in Code Page 850 is required for attachment of the 5202 to the 3197-W. Switch number 1 of switch group 2 in the printer should be set to "ON" to select the pluggable font cartridge. Switch 6 in Switch Group 2 should be set to "ON" to have the printer default to draft print mode when powered ON. Switch 1 in Switch Group 1 should be set to "ON" to select character set 2.

    Switch number 1 of Switch Group 2 in the printer should be set to "ON" in order to select the pluggable font cartridge. Switch number 5 should be set to "OFF" and switch number 6 should be set to "ON" in order to have the printer default to the draft print mode when powered ON. Switch number 1 in Switch Group 1 should be set to "ON" to select Character Set 2. For information on setting the switches in the printer, refer to the printer "Guide to Operations".

    IBM Proprinter Family

    When using the 4201 Proprinter - all models, 4202 Proprinter XL - all models, 4207 Proprinter X24E Model 2, or 4208 Proprinter XL24E Model 2 for IBM 3197 Display attachment, if the printer is powered off after the 3197 is initialized, the power off state is not detected by the display and loss of data may occur. Therefore, the printer must not be powered off after the display is initialized.

    When attaching the 4201 Proprinter II Model 2 and 4201 Proprinter III Model 3, the printer functions as an IBM 4201 Proprinter Model 001. Functions such as NLQ II are not accessible.

    When using the IBM 4201 Proprinter III Model 3 or IBM 4202 Proprinter III XL Model 003 for IBM 3197 Display attachment, the printer must be set to the IBM PC Character Set (Code Page 437).

    When attaching the 4202 Proprinter II XL Model 2 or 4202 Proprinter III XL Model 3, the printer functions as an IBM 4202 Proprinter XL Model 001. Functions such as NQL are not accessible through these displays.

    When using the 4207 Proprinter X24E Model 2 or 4208 Proprinter XL24E Model 2 for IBM 3197 Display attachment, the printer must be set to the IBM Multilingual Character Set (Code Page 850).

    When attached to the 3197 Display Station, the 4201 Proprinter, 4202 Proprinter XL, 4207 Proprinter S24E Model 2, and 4208 Proprinter XL24E Model 2 support the following languages: Austrian German, Belgian, Canadian French, Danish, Dutch, Finnish/Swedish, French, Italian, Norwegian, Portuguese, Spanish, Swiss French/Swiss German, UK English, US English, in addition to Greek, Arabic, Hebrew, Icelandic, Yugoslavian, Cyrillic, Latin2/ROECE, and Turkish.

    Refer to the IBM PC Printer and IBM Typewriter supplies catalogs, IBM Authorized dealers or IBM DIRECT for the appropriate part numbers, ordering procedures and prices.

    When ordering any of the above printers for use with the 3197, order printer cable P/N 6457008.


    Machine Elements
    Machine elements can be ordered to provide individual elements as needed by the customer in the use of the 3197.

    The video, logic keyboard, pedestal, and line cord of the 3197 Display Station can be ordered as follows:

    Machine Element
    Description P/N
    -------------------------- -------
    Video Color 6405301
    Logic 6457137
    IBM Enhanced (102-key) Kbd. 1390940
    122-key Typewriter Kbd. 1390876
    Pedestal 6457031
    Line Cord-2.8m (9.0 ft) 6952297
    Line Cord-1.8m (6.0 ft) 6952298
    Auto Termination Unit
    and Safety Covers* 94X3678
    Video Cable 6405213

    *
    Available separately as a Maintenance part only.

    (R), (TM), * Trademark or registered trademark of International Business Machines Corporation.
    ** Company, product, or service name may be a trademark or service mark of others.